Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Sci (Weinh) ; : e2307718, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38647263

RESUMO

Results from two independent clinical validation studies for measuring hemodynamics at the patient's bedside using a compact finger probe are reported. Technology comprises a barometric pressure sensor, and in one implementation, additionally, an optical sensor for photoplethysmography (PPG) is developed, which can be used to measure blood pressure and analyze rhythm, including the continuous detection of atrial fibrillation. The capabilities of the technology are shown in several form factors, including a miniaturized version resembling a common pulse oximeter to which the technology could be integrated in. Several main results are presented: i) the miniature finger probe meets the accuracy requirements of non-invasive blood pressure instrument validation standard, ii) atrial fibrillation can be detected during the blood pressure measurement and in a continuous recording, iii) a unique comparison between optical and pressure sensing mechanisms is provided, which shows that the origin of both modalities can be explained using a pressure-volume model and that recordings are close to identical between the sensors. The benefits and limitations of both modalities in hemodynamic monitoring are further discussed.

2.
Adv Sci (Weinh) ; : e2310022, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38647403

RESUMO

Minimally invasive and non-invasive hemodynamic monitoring technologies have recently gained more attention, driven by technological advances and the inherent risk of complications in invasive techniques. In this article, an experimental non-invasive system is presented that effectively combines the capabilities of spectrometry, photoplethysmography (PPG), and arterial pressure measurement. Both time- and wavelength-resolved optical signals from the fingertip are measured under external pressure, which gradually increased above the level of systolic blood pressure. The optical channels measured at 434-731 nm divided into three groups separated by a group of channels with wavelengths approximately between 590 and 630 nm. This group of channels, labeled transition band, is characterized by abrupt changes resulting from a decrease in the absorption coefficient of whole blood. External pressure levels of maximum pulsation showed that shorter wavelengths (<590 nm) probe superficial low-pressure blood vessels, whereas longer wavelengths (>630 nm) probe high-pressure arteries. The results on perfusion indices and DC component level changes showed clear differences between the optical channels, further highlighting the importance of wavelength selection in optical hemodynamic monitoring systems. Altogether, the results demonstrated that the integrated system presented has the potential to extract new hemodynamic information simultaneously from macrocirculation to microcirculation.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38082590

RESUMO

The right internal jugular vein is connected to the right atrium of the heart via the superior vena cava, and consequently its pressure, known as the jugular venous pressure or the jugular venous pulse (JVP), is an important indicator of cardiac function. The JVP can be estimated visually from the neck but it is rather difficult and imprecise. In this article we propose a method to measure the JVP using a motion sensor patch attached to the neck. The JVP signal was extracted from the sensor's 3-axes gyroscope signal and aligned with simultaneously measured ECG and seismocardiogram signals.The method was tested on 20 healthy subjects. The timings of the characteristic JVP waves were compared with the ECG R peaks and seismocardiogram heart sounds S1 and S2. The JVP was reliably measured from 18 subjects with all three waves identified. The timings of the waves were also physiologically plausible when compared to the ECG R peak and the heart sounds. Importantly, the JVP was also found to modulate with respiration, further indicating that the measured signal was indeed the JVP and not the carotid pulse.The results show that the JVP can be measured with a wearable patch-like device registering the delicate motions of the right internal jugular vein. The method has potential to be developed into a clinical tool to measure cardiac health in diseases such as heart failure and chronic obstructive pulmonary disease (COPD).Clinical relevance-The developed method could enable an affordable measurement of clinically important cardiac parameter, jugular venous pulse, as a part of a routine examination.


Assuntos
Insuficiência Cardíaca , Veia Cava Superior , Humanos , Fenômenos Fisiológicos Cardiovasculares , Pressão Venosa Central/fisiologia , Átrios do Coração
4.
iScience ; 26(11): 108295, 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-38026187

RESUMO

Our aim is to develop a blood pressure (BP) measurement technology that could be integrated into a finger-worn pulse oximeter, eliminating the need for a brachial cuff. We present a miniature cuffless tonometric finger probe system that uses the oscillometric method to measure BP. Our approach uses a motorized press that is used to apply pressure to the fingertip to measure BP. We verified the functionality of the device in a clinical trial (n = 43) resulting in systolic and diastolic pressures ((mean ± SD) mmHg) of (-3.5 ± 8.4) mmHg and (-4.0 ± 4.4) mmHg, respectively. Comparison was made with manual auscultation (n = 26) and automated cuff oscillometry (n = 18). In addition to BP, we demonstrated the ability of the device to assess arterial stiffness (n = 18) and detect atrial fibrillation (n = 6). We were able to introduce a sufficiently small device that could be used for convenient ambulatory measurements with minimal discomfort.

5.
IEEE Rev Biomed Eng ; 16: 424-438, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35015647

RESUMO

Hypertension, or elevated blood pressure (BP), is a marker for many cardiovascular diseases and can lead to life threatening conditions such as heart failure, coronary artery disease and stroke. Several techniques have recently been proposed and investigated for non-invasive BP monitoring. The increasing desire for telemonitoring solutions that allow patients to manage their own conditions from home has accelerated the development of new BP monitoring techniques. In this review, we present the recent progress in non-invasive blood pressure monitoring solutions emphasizing clinical validation and trade-offs between available techniques. We introduce the current BP measurement techniques with their underlying operating principles. New promising proof-of-concept studies are presented and recent modeling and machine learning approaches for improved BP estimation are summarized. This aids discussions on how new BP monitors should evaluated in order to bring forth new home monitoring solutions in wearable form factor. Finally, we discuss on unresolved challenges in making convenient, reliable and validated BP monitoring solutions.


Assuntos
Doenças Cardiovasculares , Hipertensão , Humanos , Pressão Sanguínea , Monitorização Ambulatorial da Pressão Arterial/métodos , Hipertensão/diagnóstico , Determinação da Pressão Arterial/métodos
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 7441-7444, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34892816

RESUMO

Blood pressure monitoring using a traditional arm cuff device is often inconvenient and possibly painful. We present a miniature cuffless tonometric finger probe system, that uses the oscillometric method to measure blood pressure (BP). A small enough device could be used for convenient ambulatory measurement and be worn during sleep with minimal discomfort. In addition to BP, the device is able to collect arterial pulse wave data that can further be used to derive other cardiovascular parameters, such as heart rate (HR), heart rate variability (HRV) and central aortic systolic pressure (CASP). The device uses a motor controlled press that is used to apply pressure to the finger tip to measure the oscillometric response. We verified the functionality of the device by proof-of-concept measurements. Lastly we evaluate methods for further developing the concept and discuss the future directions.


Assuntos
Pressão Arterial , Determinação da Pressão Arterial , Pressão Sanguínea , Miniaturização , Oscilometria
7.
Biosens Bioelectron ; 167: 112483, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-32818750

RESUMO

Despite blood pressure being one the leading modifiable risk factors for cardiovascular disease and death, it is severely under-monitored. For this challenge we propose a finger artery non-invasive tono-oscillometric monitor (FANTOM) which is an automated low-cost instrument for measuring blood pressure and hemodynamic parameters from the fingertip. The sensing technology is highly scalable and could be integrated to a pulse oximeter probe for increased patient comfort. A tonometric cuff-less mechatronic system is used to apply pressure on the fingertip for (i) measuring oscillometric blood pressure, (ii) recording arterial waveform and for (iii) constructing central blood pressure (CBP) waveform. Clinical study on volunteers (n = 33) was performed against a commercially available arm cuff device yielding systolic and diastolic readings ((mean±SD) mmHg) of (-0.9 ± 7.3) mmHg and (-3.3 ± 6.6) mmHg respectively. The results comply with the Association for the Advancement of Medical Instrumentation (AAMI) standard for non-invasive blood pressure monitors. The arterial pulse recording morphology was compared against a volume clamp device (CNSystems CNAP 500) (n = 3) resulting in similar performance. Comparison of CBP against a pulse wave analysis (PWA) device (Atcor Medical Sphygmocor XCEL) (n = 5) revealed central aortic systolic pulse (CASP) and central augmentation index (cAIx) estimates with precision and accuracy of (2.0 ± 3.7) mmHg and (1.4 ± 6.2)% respectively. In conclusion, the results indicate that the proposed technology could be useful in the development of new portable or wearable blood pressure monitors. The sensing technology is highly scalable and could be integrated to a pulse oximeter probe for increased patient comfort.


Assuntos
Técnicas Biossensoriais , Determinação da Pressão Arterial , Pressão Sanguínea , Frequência Cardíaca , Humanos , Oscilometria
8.
NPJ Digit Med ; 2: 39, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31304385

RESUMO

There is an unmet clinical need for a low cost and easy to use wearable devices for continuous cardiovascular health monitoring. A flexible and wearable wristband, based on microelectromechanical sensor (MEMS) elements array was developed to support this need. The performance of the device in cardiovascular monitoring was investigated by (i) comparing the arterial pressure waveform recordings to the gold standard, invasive catheter recording (n = 18), (ii) analyzing the ability to detect irregularities of the rhythm (n = 7), and (iii) measuring the heartrate monitoring accuracy (n = 31). Arterial waveforms carry important physiological information and the comparison study revealed that the recordings made with the wearable device and with the gold standard device resulted in almost identical (r = 0.9-0.99) pulse waveforms. The device can measure the heart rhythm and possible irregularities in it. A clustering analysis demonstrates a perfect classification accuracy between atrial fibrillation (AF) and sinus rhythm. The heartrate monitoring study showed near perfect beat-to-beat accuracy (sensitivity = 99.1%, precision = 100%) on healthy subjects. In contrast, beat-to-beat detection from coronary artery disease patients was challenging, but the averaged heartrate was extracted successfully (95% CI: -1.2 to 1.1 bpm). In conclusion, the results indicate that the device could be useful in remote monitoring of cardiovascular diseases and personalized medicine.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...